EL MISRIA ENGINEERING

Ritar HR Series Lead-Acid Batteries

page

Ritar HR Series Lead-Acid Batteries

High-Rate Discharge Batteries for UPS & Critical Power Applications

The Ritar HR Series is a high-rate discharge valve-regulated lead-acid battery range engineered for applications where reliable backup power and high-current discharge performance are essential.

Designed with reinforced grids and specially formulated active materials, HR Series batteries provide stable performance during demanding discharge conditions. The series is particularly suitable for UPS and EPS systems, data centers, emergency power systems, telecommunications infrastructure and other critical power applications.

For high-load applications, the HR Series provides higher power output than conventional battery ranges while maintaining reliable standby performance.

Key Features

High-Rate Discharge Performance

Optimized for applications requiring high current during short-duration backup events, making the HR Series particularly suitable for UPS systems and critical power infrastructure.

Extended Design Life

The HR Series offers a design life of approximately 8–15 years at 25°C, depending on the model and operating conditions.

High Power Density

The battery construction is optimized to deliver increased power output in high-rate discharge applications, supporting demanding UPS loads and reducing the space required for battery installations.

Advanced AGM Technology

A high-pressure AGM separator design helps reduce internal resistance and provides controlled assembly pressure, contributing to stable performance and improved battery durability.

Wide Operating Temperature

The HR Series is designed for operation from approximately -20°C to 60°C, allowing it to perform reliably across a wide range of environmental conditions.

Durable Battery Construction

The battery case is manufactured using impact-resistant ABS material, with optional flame-retardant construction available for applications requiring enhanced fire-safety characteristics.


HR Series Technical Highlights

Parameter Specification
Battery Technology Valve-Regulated Lead-Acid / AGM
Application High-Rate Discharge
Voltage Class 6V / 12V
Capacity Range 16W – 850W
Design Life at 25°C 8–15 Years
Reaction Efficiency >99%
Self-Discharge Approx. 3% / Month
Operating Temperature -20°C to +60°C
Main Application UPS / EPS / Critical Power

Specifications are based on the current Ritar HR Series product information and should be confirmed against the exact battery model before quotation or installation.

Available HR Series Models

 

Applications

UPS Systems

Ideal for backup battery banks in online and critical UPS installations where high-current discharge performance is required.

Data Centers

Suitable for critical infrastructure requiring dependable DC backup power during utility interruptions.

EPS Systems

Provides high-rate backup power for emergency power supply systems.

Telecommunications

Suitable for backup power applications where reliable standby and high-current discharge capability are required.

Emergency & Critical Power

Can be integrated into systems supporting emergency lighting, control systems and other critical electrical loads.


Why Choose HR Series Batteries?

High Power Output
Designed for demanding high-rate discharge applications.

Reliable Backup Power
Provides dependable energy storage for critical power systems.

Long Design Life
Up to 15 years design life under specified conditions.

Wide Temperature Range
Designed to operate across a broad temperature range.

AGM Construction
Maintenance-free VRLA/AGM technology suitable for modern UPS installations.

Multiple Voltage & Power Options
Available in 2V, 6V and 12V configurations with multiple power ratings.

Battery Selection for UPS Systems

Selecting the correct battery for a UPS requires more than simply matching voltage. Battery selection should consider:

  • UPS rated power
  • Required backup time
  • DC bus voltage
  • Battery string configuration
  • Discharge rate
  • Ambient temperature
  • Installation space
  • Required battery life
  • Load characteristics
  • Manufacturer discharge curves

EL MISRIA Engineering can assist with battery sizing and selection according to the UPS rating, required autonomy time and site conditions.

Engineering & Battery Services

EL MISRIA Engineering provides technical support for critical power systems, including:

  • UPS battery replacement
  • Battery bank sizing
  • Battery supply
  • Battery installation
  • Battery inspection
  • Preventive maintenance
  • UPS troubleshooting
  • On-site technical support
  • Emergency UPS services

Our existing service offering includes commissioning, on-site repair, spare-parts supply, in-house UPS repair, on-site battery supply, scheduled maintenance and technical support.

Request a Battery Solution

Looking for the correct battery for your UPS system?

Contact EL MISRIA Engineering for battery selection, sizing and quotation.

Provide us with:

  • UPS manufacturer and model
  • UPS capacity (kVA/kW)
  • Existing battery voltage
  • Existing battery model
  • Required backup time
  • Number of batteries
  • Installation location

Our engineering team can recommend a suitable HR Series configuration for your application.

Contact EL MISRIA Engineering